UT5300X Series Programmable Hipot Tester

Belonging Category:

UNI-T

Product Inquiry
  • Product Description

    Features:

    ● 4.3-inch TFT LCD, simple panel operation

    ● Single-channel testing

    ● Support AC/DC hipot test, IR insulation test*

    ● 5kVAC/20mA, 6kVDC/10mA

    ● IR:5kV/20mA,200kΩ~10GΩ

    ● Arc detection function

    ● Automatic discharge test function

    ● Voltage ramp-up and ramp-down function, the test waiting time can be set arbitrarily for insulation resistance

    ● Preset upper and lower limits, intelligent judgment, sound and light alarm

    ● The DC withstand voltage test has the function of rapid discharge to avoid the risk of electric shock caused by the residual voltage on the DUT

    ● Anti-electric wall technology detects the circuit at any time to prevent electric shock damage and ensure the safety of personnel

    ● Over-voltage, over-current protection, current base zero function

    ● It can store 100 test files, each file can store 20 test steps, and the test mode can be arbitrarily combined

    ● Support SCPI and MODBUS protocols, which is convenient for components to automate the test system

    ● Equipped with Handler (PLC) interface for industrial control, RS485 (option), RS-232C and LAN interface for connecting to computer

     

    Basic parameters

    Standard package quantity

    Brown box: 1 set

    Standard accessories

    1 power cable; 1 high-voltage rod test line (small & no switch); 1 RS-232 communication line;
    a pair of red and black test clips; 2 spare fuses

    Optional accessories

    UT-L63 High Voltage Bar Test Lead; UT-L62 remote control high voltage rod test lead

    Body Dimensions (W×H×D)

    280mm×88mm×428mm

    Body Dimensions (W×H×D)

    10.7kg

    UT5320R+:12.9kg

     

    Technical Indicators

    Basic functions

    UT5310A+

    UT5310D+

    UT5310R+

    UT5320R+

    Output voltage

    AC

    Voltage range

    0.050kV-5.000kV

    Voltage waveform

    Sinusoid

    Distortion

    <3%

    Operating frequency

    50, 60Hz optional

    Frequency accuracy

    ±1%

    Output power

    50VA(5.000kV10mA)

    100VA(5.000kV20mA)

    Voltage regulation

    ± (1.0% 50V) (rated power)

    DC

    Voltage range

    -

    0.050 kV-6.000kV

    Source frequency

    -

    600Hz

    Output power

    -

    30VA(6.000kV5mA)

    60VA(6.000kV10mA)

    Voltage regulation

    -

    ± (1.0% 100V) (rated power)

    AC/DC

    Voltage resolution

    -

      1V

    Voltage output accuracy

    -

    ± (1.0% setting 5V) (no load)

    Voltage Test Accuracy

    -

    ± (1.0% m.v. 5V)

    How the voltage is generated

    -

    DDS signal source plus Class AB power amplifier

    Current test range

    AC

    Current range

    0.001mA-10mA

      0.001mA-20mA

    Short-circuit current
    (Instantly)

          >20 mA
    (Set output voltage>500V)

           >40 mA
    (Set output voltage>500V)

    Current resolution

    0.001 mA

    Current accuracy

    ± (2.0% reading 5 digits)

    Actual current

    OFF,0.001 mA-10mA

    OFF,0.001 mA-20mA

    DC

    Current range

     

    0.1μA-5.00mA

      0.1μA-10.00mA

    Current accuracy

     

    ± (2.0% reading 5 digits)

    Discharge function

     

    Automatic discharge after the end of the test

    Insulation resistance test

    Output voltage

    -

    0.050kV-2.500kV (optional 5.000kV)

    Voltage resolution

    -

    1V

    Voltage Test Accuracy

    -

    ± (1.0% m.v. 2V)

     

    Basic Functions

    UT5310A+

    UT5310D+

    UT5310R+

    UT5320R+

    Maximum output current

    -

    5mA

    10mA

    Maximum output power

    -

    12.5VA(2500V/5mA)

    25VA(2500V/10mA)

    Instantaneous short-circuit current is output

    -

    >10mA(Set the output voltage> 500V)

    >20mA(Set the output voltage> 500V)

    Load regulation

    -

    ≤1% (rated power)

    Ripple (1kV)

    -

    ≤3% (1kV, no load)

    Discharge function

    -

    Automatic discharge after the end of the test

    Resistance measurement range

    -

    0.2MΩ-10GΩ

    0.1MQ-10GQ

    Current measurement accuracy

    -

    ± (1.5% reading, 5 digits) (after zero)

    Arc detection

     

    Measuring range

    AC

    OFF, levels 1-9

    DC

    OFF, levels 1-9

    Comparators

    The upper limit of the current is set on I

    AC

    0.001mA-10mA

    0.001mA-20mA

    DC

    0.1μA-5mA

    0.1μA-10mA

    The lower current limit is set under I
    (LOWER OFF)

    AC

    0.001mA-10mA

    0.001mA-20mA

    DC

    0.1μA-5mA

    0.1μA-10mA

    Resistance upper limit setting

    OFF-0.1MΩ-10GQ

    The lower limit of resistance is set

    0.01MΩ-10GΩ

    Discriminant output

    Pass/Fail Lcd And Led Are Displayed Separately, And Audible Alarms Are Provided

    Parameter setting

    Voltage rise time

    0.1s-999.9s

    Voltage dip time

    0s-999.9s, (only after withstand voltage PASS)

    Voltage wait timev

    0.3s-999.9s (DC withstand voltage only, and meet the rise time, test time> waiting time)

    Test time setting

    0.1s-999.9s (at TIMER ON)

    Temporal accuracy

    ± (0.2% setpoint±0.1s)

    Measurement function

     

    Keypad lock

    Prevent accidental modification of test conditions, or prohibit test conditions from being modified

    Base zeroing function

    The current flowing through the insulation resistance and distributed capacitance between the output lines can be cleared

    Start wait delay

    At the beginning of the test (START is pressed), the high-voltage start signal is output first, and the high-voltage output is started after waiting for a certain period of time

    Current over-range judgment

    The hardware can quickly determine insulation collapse, which is faster and safer than voltage sampling, and reduces the impact damage to the measured product

    ARC arc detection

    Sample the sudden change signal of the current to determine the potential hidden danger and approximate scale of the loop

    Ground current detection

    In case of accidental electric shock or high voltage leakage to the shell, protect personal safety

    Alarm volume adjustment

    Off, Low, Medium, High

    High voltage indication

    Window indication and LED light indication

    Storage & Interfaces

    File programming and storage

    Programmable 100 test files, each file can be set with 20 test steps

    USB interface

    Yes (up to 128G)

    Boot parameters are saved

    The set parameters are saved as the default parameters, and they can be automatically restored the next time the computer is turned on

    Control interface

     HANDLER,SIGNAL,LAN,RS-232

    Communication protocols

    SCPI,Modbus    RTU

    Communication interface

    RS-232C, optional RS485