UTS5000A Series Signal Analyzers

Belonging Category:

UNI-T

Product Inquiry
  • Product Description

    Features:

    ● Frequency range of spectrum analysis: 9kHz~13.6GHz/26.5GHz

    ● Display average noise level DANL up to -163 dBm

    ● Phase noise: <-107 dBc/Hz@10kHz offset

    ● The maximum number of scan points is 100001 points

    ● Minimum resolution bandwidth 1 Hz

    ● Selectivity < 4.1:1

    ● Advanced One-Click Measurement (Option)*

    ● EMI Pre-Scan Analysis (Option)*

    ● Analog Demodulation Analysis (Option)*

    ● Vector Signal Analysis (Option)*

    ● Real-time spectrum analysis (option)*

    ● I/Q Analysis (Option)*

    ● Equipped with 15.6-inch 1920x1080 HD capacitive touch screen

    ● Web control, multi-device synchronization, presentation monitoring, etc. Rich peripheral interfaces: support keyboard, mouse, storage, host computer, remote control

    1. The UTS5000A series shows that the average noise level is as low as -163dBm, and the excellent sensitivity can effectively test weak signals

     

    2、Provides Up To 100001 Scan Points For Higher Frequency Resolution And Easier Capture Of Hard-To-See Signals

     

    3、Excellent Selectivity Of Less Than 4.1:1

     

    4、EMI pre-compliance and conformance testing

     

    5、15.6-inch high-definition capacitive touch display, support gestures such as zooming, expanding, dragging and other gestures to the spectrum trace, touch editing of menus, etc

     

    6、Detachable Dust Filter

     

    Product Parameters

    (W×H×D)

    445×31×195 mm

    Weight

    11kg

    Adjust The Interval

    The Recommended Calibration Interval Is One Year

    Accessories Are Standard

    Power Cable ×1 And Usb Data Cable ×1 In Accordance With The National Standard;

     

    Features:

    Basic Functions

    UTS5013A

    UTS5026A

    Frequency Range

    9kHz~13.6GHz

    9kHz~26.5GHz

    10MHzInternal Frequency Reference

     

    Base Frequency

    10.000000MHz

    Reference Frequency Accuracy

    ± [(Time from last calibration × Frequency aging rate) Temperature Stability Initial Accuracy ]

    Temperature Stability

    20 To 30 °C

    ±3×10-8

    Full Temperature Range

    ±3×10-8

    Frequency Aging

    ±3×10-7/year (first year)

    Achievable Initial Calibration Accuracy

    ±8×10-8

    Sampling Frequency Reference Accuracy

    ±(3×10-7+3×10-8+8×10-8)

    1 Year Since The Last Calibration

    ±4.1×10-7

    FM Remaining

    ≤ 1Hz p-p, nominal within 20ms

    Frequency readings (start, cut-off, center,

    Cursor)

    Cursor resolution

    Sweep Frequency / (Number of Scan Points -1)

    Cursor Frequency Readout Accuracy

    ±[Cursor Frequency Reading× Reference Frequency Accuracy 0.25% × Sweep Width 5% ×Resolution Bandwidth Cursor Frequency Resolution 0.5 Horizontal Resolution]

    Cursor Mode

    Normal, Difference, Fixed, Relative

    Cursor Function

    Noise cursor, in-band power, in-band density, N dB, frequency meter

    Frequency Counter Uncertainty

    ±[ Cursor Frequency Readings × Base Frequency Accuracy Frequency Counter Resolution ]

    △ Counter Accuracy

    ±[ Δ Frequency Reading × Reference Frequency Accuracy 0.141hz ]

    Frequency Sweep Width (Fft And Sweep Modes)

     

    Sweep Range

    0hz (Zero Sweep Width), 10hz To 26.5ghz

    Scan & Trigger

     

    Scan Time Range

    Sweep Width=0Hz

    1μs至4000s

    Sweep Width≥10Hz

    1ms至4000s

    Scanning Accuracy

    Sweep Width≥10Hz,Scan mode

    ±0.01%Nominal Value

    Sweep Width≥10Hz,FFT

    ±40% Nominal Value

    Sweep Width=0Hz

    ±1% Nominal Value

    Scan Rules

    Continuous, Single

    Resolution Bandwidth (Rbw)

     

    Range (-3 dB bandwidth)

    1 Hz to 3MHz (10% steps), 4, 5, 6, 8MHz